Prince Premium SWR Systems with sliding socket joint are manufactured
in dark grey color in 40mm, 50mm, 63mm, 75mm,
90mm, 110mm, 160mm dia sizes,
with overall standard length of 3 metres. These
pipes conform to indian standards IS: 13592 and
are designed to withstand continuous internal
hydraulic pressure of 4kgf/cm so as to ensure
life-long trouble- free working.The pipes are
provided with an integral rubber ring type socket
at one end while other end is kept plain, smooth
and free from burrs. Rubber ring type socket ends
provide easy push-fit type joining. Simultaneously,
allowance for thermal expansion can also be provided
during installation.
Pipe
clips
The
special design of PRINCE pipe clips keep Prince Premium SWR Pipe & Fittings away from the building
wall, making the building and pipes and fittings,
maintenance easy, without SWR messing up the building
exteriors.
Rubber
Seal Rings For Joints And Access Doors
Manufactured
in accordance with IS: 5382 for 50mm, 75mm, 90mm,
160mm sizes. These are made out of natural rubber
with a shore `A' hardness of 50 ± 5 provide
superior resistance to biological attack. Special
design of cross section ensure perfect sealing.
Lubricant
Available in 100gms and 500 gms packing. Specially
formulated for compatability with rubber seal
as well as PVC.Does not support the growth of
bacteria or fungi.
Installation
Methods
Above
Ground Installation
PRINCE uPVC
Pipe Clips should be used with a spacing of about
900mm for vertical laying. Use of fitting with
door and cleaning pipe may be made at suitable
points to provide access for inspection and cleaning.
Underground
Installation
For
laying uPVC Pipes in trenches, trench width should
not be less than pipe diameter plus 300mm, while
trench depth should be about 600 to 1000mm, depending
upon the size of the pipe and slope required for
gravity flow. Care should be taken to avoid dirt
entering the joints. Pipelines should not be laid
on submerged rock. Testing of the line should
be done before filling back the trench.
Concealed
Installation
For
concealing the drain lines, slots are made in
the wall or concrete.The slot size should be such
that the system remains stress free at the time
of installation. Sharp edges should be avoided.
UPVC Pipes and Fittings should be cleaned and
a light coat of solvent cement applied externally
before they are inserted in the slots. Sprinkle
dry sand on them to form a good base for proper
fixing with cement. Leakage test must be carried
out before concealing the system.
Subsequent
Installation
Branch
lines can be provided to existing SWR system using PRINCE fitting,
such as 'y' or 't'. Use of single or Double repair
coupler is made for this purpose.
Testing
Before Use
Before
the systems is put into use, it should be tested
for leakages by air test hydraulic test or smoke
test.
Maintenance
Once
installed Prince Premium SWR Systems require no maintenance. However,
threaded door caps with rubber ring seals are
provided on fitting for easy access while cleaning.
Small breakages in the pipe can be repaired by
fixing two halves of a PVC pipe on the damaged
portion with a new piece of pipe using two repair
couplers.
Storage
To avoid
any possibility of damage to uPVC Pipes and fittings,
a few points should be kept in mind.
• Pipes and fitting should not be kept
on sharp objects.
• Lift, do not drag pipes and fitting.
• Fittings should be stored in cartons
or bags.
• Pipes should stacked on an even surface,
the stacking height not exeeding
1.5 meters if they have to be stored for
a long period.
• Rubber ring should be kept tension free.
• Lubricants and solvent
cement should be stored in a cool place, away
from
direct sunlight.
|